Contact us

  • Add:No.7508 North Jiasong Road, Jiading District, Shanghai
  • Tel:0086-21-39531213
  • Fax:0086-21-39531626
  • E-mail:info@yinuochina.com

Other Flow Meter

Your Position:Home > PRODUCTS > Other Flow Meter
LXW Vortex Flow Meter
  • LXW Vortex Flow Meter

LXW Vortex Flow Meter

LXW Serial vortex flowmeter is manufactured according to the principle of Karman vortex principle together with latest digital transmitter (DSP technology)...


Description

  • Introduction
  • Flow Range
  • Outline Dimension
  • Model Selection

LXW Serial vortex flowmeter is manufactured according to the principle of Karman vortex principle together with latest digital transmitter (DSP technology). It is widely used to measure liquid, gas, steam flow in the closed pipeline because the original detection is sealed in the test body, no contact with the measured medium and there is no lining material and moving parting, it does not need on-site maintenance and it is very popular with the majority of users in industries of oil, petrochemical, water/waste water treatment, metallurgy, pharmacy, thermoelectric, etc. for process control and measurement management.

 

Feature And Main Technical Datum

●Compact structure
●No moving parts, long service time
●Long time stability
●Same sensor can measure liquid, gas and steam
●Whith acceptable Reynold number, the meter coefficient is free from the influence of the change of temperature, pressure, viscosity and others.
●Reynolds No. Range:2X104~7X106(For DN25~DNl00)
4X104~7X106(For DNl50~DN300)
●Display: to display instant and total Flow
●Working Pressure:1.6~32MPa
●Medium Temp.: 0℃~+150℃(Integral Type)
+100℃~+300℃(Hight temp. Type)
●Ambient Temp.:-25℃~+60℃
●Power:24VDC ±10% Or 220VAC
●Relative Humidity:5%~95%
●Atmospheric Pressure:86~106KPa
●Measurable Fluid: liquid, gas and steam
●Accuracy:1%(For Liquid), 1.5%(For Gas and Steam)
●Output Signal:4~20mA Current(2 Wire System) Or
Standard Pulse Output(3 Wire System)
Digital Communication Modbus RTU
Analog signal
●Anti-explosion Grade: ExdⅡBT4
●Anti-explosion Certificate No.:GYB 081788
●LCD digital display (read in L/min, m3/h, kg/h, etc.)

 

Principle
Put a drum vertically into a burette and let some fluid flow down along the drum, by two sides of which there formed, in rotation, regular vortexes , which is called the Karman Vortex Street. An output frequency of the Karman Vortex Street is related to fluid velocity and drum diameter, which can be described by following formula:

F=St·
Where,
f-Output frequency of the Karman Street
St-Coefficient (called as Strohar number)
v-velocity
d-Diameter of drum

As an output frequency of the Karman Vortex Street f is direct proportional to a velocity v. It may work out an instantaneous flow rate by using a tested output frequency of the Karman Street. The Strohar number is a key coefficient for vortex street flow meters. Within the lineal section of the curve, where St≈0.17, the output frequency is direct proportional to the flow velocity, so a velocity v is derivable by using a tested frequency f.
LXW serials vortex street flow transducers detect the output frequency by using piezoeletricial elements inside the sensors (probes) to test the stress that is alternatively acted on the elements by vortex.

Flow Range (General Fluid)

Note:The outfactory calibrated fluid is water or air.

 

Flow Range Of Saturated Steam

Outline Dimension
Wafer Connection Type (See Picture 3 and Table 3)

 

Flange Connection Type (See Picture 4 & Table 4)

 

Straight Pipe length Requirement

Note: D-Means the nominal diameter of flowmeter
If need install temperature sensor and/or pressure sensor in the pipe system, the sensor should be installed the down flow of the flowmeter as the below picture shown.

model selection

 

Example: LXW-05ZY1.6JBFWX
Flowmeter in diameter of DN50, to measure liquid,
1.6MPa, wafer type, anti explosion type,
pulse output,power supply:24V, with local display.

 

Ordering Information
1.Nominal Diameter:DN_____mm
2.Fluid Name:_________________________
3.Flow :Max.:_____ m3/h Normal_______ m3/h Min._______m3/h
4.Fluid Temp.: __________℃
5.Working Pressure: __________MPa
6.Fluid Density:_________________g/cm3
7.Output Signal:_________________

Previous:LTD General Electron Flow Meter